Set it to 200 ohms. (lowest setting). If you have a symbol .) ) ) Set it to that instead of 200 ohm. That is a buzzer.

Put the black plug into the COM jack. Put the red plug into the VΩmA Jack. Does not matter which probe you use to touch terminals. One probe on one Ign switch terminal, other probe on another ign switch terminal. Assign a letter to each of the terminals A, B and C. u] Hold probes on the terminals for several seconds, let the reading settle. [/u]

You can use tape on the terminals with A, B and C marked if you wish. Any method to keep track.

You can touch the two probes together before you start to hear beep or see a value on the screen as a test. You will hear a beep or see a value on the display.

What are the readings or beeps between these sets (SWITCH OFF):

A and B (one probe on A , one probe on B)

A and C (one probe on A, one on C)

B and C (one on B, one on C)

Do the test again at 2000 Ohms

Give exact results Like 2.0 or 0.2 or .001 or 0.00 or 000..whatever

Bottom line is that you can't hurt anything as long as you put 33 and 30 on different terminals. Even then you wouldn't hurt anything, but you won't be able to turn motor off.


Right is right, even if everyone is against it, and wrong is wrong, even if everyone is for it. - William Penn