| |
Labor Day Putting down your wrenches or time for MORE wrenching? 
Plenty of places to share. | | Click on image for the lowdown. 
====
| | |
2 members (TexasJim50, Joe W),
38
guests, and
4
robots. | | Key: Admin,
Global Mod,
Mod | | | Forums66 Topics128,010 Posts1,055,299 Members48,419 | | Most Online14,466 Apr 26th, 2026 | | AD Chevy Trucks Over 6,000 pictures Brad Allen has an awesome collection of Chevrolet factory pictures that he has set up from film strips. Check them out!
Lots of work on Brad's part ... pure enjoyment (and references) for you!
| | THANKS!
For helping keep this great
old truck web site
on the Internet for over 30 years! and not clogged down with Ads! Again, thanks! | | | | Joined: Jun 2012 Posts: 142 'Bolter | | 'Bolter Joined: Jun 2012 Posts: 142 | Have two sets of gauges from the T F series (55-59)How do i bench test them? One temp. gauge is sender attached to solid wire(copper/aluminum) Other unit is sender with electric wire to gauge. The rest of the gauges are all the same. | | | | | Joined: May 2005 Posts: 8,983 Sir Searchalot | | Sir Searchalot Joined: May 2005 Posts: 8,983 | Well as far as temp gauges it sounds like you have one mechanical and one electrical. One with a tube and one with a wire. They are best tested buy putting the "sender" part in water over a heat source and watch gauge compared to a thermometer in the water container. Take it to boil and back down while observing. The electric is more trouble: You can use a battery or a battery charger for the electric one while in the water. (submerge only the threaded portion). Read this: http://www.madelectrical.com/workshop/water-temp-gauge.shtml
Right is right, even if everyone is against it, and wrong is wrong, even if everyone is for it. - William Penn | | | | | Joined: Sep 2001 Posts: 29,269 Bubba - Curmudgeon | | Bubba - Curmudgeon Joined: Sep 2001 Posts: 29,269 | I think the electrical temperature sender started being used in 1956.
What year head do you have?
The mechanical sender might need a brass bushing to fit into the head that used the electrical sender. Check the outer diameter of the sender bases.
| | | | | Joined: Jun 2012 Posts: 142 'Bolter | | 'Bolter Joined: Jun 2012 Posts: 142 | The head is a 56. Thanks for the advice. | | | | | Joined: Sep 2001 Posts: 29,269 Bubba - Curmudgeon | | Bubba - Curmudgeon Joined: Sep 2001 Posts: 29,269 | Do both types of senders fit into that head, with no adapter?
The 1955-2nd Task Force Truck "mechanical" sender might have a wider diameter than the earlier mechanical senders. That would be interesting to know.
| | | | | Joined: Dec 2000 Posts: 3,399 Gas Pumper | | Gas Pumper Joined: Dec 2000 Posts: 3,399 | I just know that the electrical sender fits in the block with no adapter. Not sure about the mechanical one. | | | | | Joined: Jun 2004 Posts: 8,597 Riding in the Passing Lane | | Riding in the Passing Lane Joined: Jun 2004 Posts: 8,597 | I would sure use the electrical gauge if possible. I was thinking the mech gauge used on 6 cyl. & the electric on v-8. They say money can't buy happiness. It can buy old Chevy trucks though. Same thing. 1972 Chevy c10 Cheyenne SuperIn the Gallery Forum | | | | | Joined: Jun 2012 Posts: 142 'Bolter | | 'Bolter Joined: Jun 2012 Posts: 142 | Yes both senders fit in the head w/o adapter It is on a 235. | | | | | Joined: Sep 2001 Posts: 29,269 Bubba - Curmudgeon | | Bubba - Curmudgeon Joined: Sep 2001 Posts: 29,269 | Thanks for that info, Midpiner | | |
| |
| |