#90622 03/15/2004 10:15 AM | Joined: Feb 2004 Posts: 60 Member | | Member Joined: Feb 2004 Posts: 60 | While re-wiring my truck I found a wire running from the pos side of the coil directly to the side terminal of the starter switch.
The truck runs with the wire there and without, so for the time being it has been removed.
Any idea what this wouldve been installed for?
Thank you, Jason | | |
#90623 03/15/2004 3:24 PM | Joined: Jul 2001 Posts: 3,887 Cruising in the Passing Lane | | Cruising in the Passing Lane Joined: Jul 2001 Posts: 3,887 | supplies batt voltage to the coil when the starter is engaged - otherwise voltage is supplied thru the ignition resistor and is less than 12v - will work fine w/o that wire until there's a condition that makes the motor reluctant to start, when it won't - wires w/ unknown purposes are everywhere  it's a conspiricy to make life seem complicated!! rip'em all out! Bill | | |
#90624 03/15/2004 10:38 PM | Joined: Feb 2004 Posts: 60 Member | | Member Joined: Feb 2004 Posts: 60 | | | |
| |
| |