on the Internet for over 30 years! and not clogged down with Ads! Again, thanks! | | | | Joined: Dec 2011 Posts: 241 'Bolter | | 'Bolter Joined: Dec 2011 Posts: 241 | I am looking for some advise on a compressor. I have been debating wether to upgrade my existing compressor to something larger. I am weighing the options of being able to do some sand blasting and also some painting of my truck, compared to paying for it to be done. I would like to be able to prime and possibly shoot a bottom coat of paint in preparation of having it finish coated. The question I have is what would be the minimum gallon capacity and CFI requirements at what pressure? I don't have 3 phase available but do have a 100 amp 240 volt service in my shop. Any advice would be appreciated. | | | | | Joined: Aug 2005 Posts: 6,377 Ex Hall Monitor | | Ex Hall Monitor Joined: Aug 2005 Posts: 6,377 | Man this get discussed a lot. Searching the site using compressor as the search term will get you hours of reading. The short answer is to take the CFM requirement of the largest air hog tool you will use and buy a compressor that matches that "continuous". For example if your highest requirement tool uses 12CFM @ 90 PSI you'll need a compressor that has at least that rating continuous.
Save a life, adopt a senior shelter pet. The three main causes of blindness: Cataracts, Politics, Religion. Name your dog Naked so you can walk Naked in the park.
| | | | | Joined: Oct 2010 Posts: 171 Wrench Fetcher | | Wrench Fetcher Joined: Oct 2010 Posts: 171 | Agree with what Tiny said above. Minimum Ingersoll Rand Single Stage T-30(or now they call it a SS5L5, 5.0-HP, 60-Gal. Vertical 18.1CFM@90psig, 135PSI max,230V,60amp,single phase) A step up would be a two-stage 2475N7.5-V 7.5HP 80-Gal. Vertical 24.0CFM@90psig 175PSI max,230V,60amp,single phase. 3 Phase would cost a big nut to have brought in, New panel/line wire, don't think it would be worth it. Niether one of these would sandblast a car, um truck, but would blast a bunch O truck parts and would paint a truck without a problem. We have had a SS5L5 for 15 years and no problems-it's used 5 days a week/10 hours a day. Now I know I will get a lot of input on this  , but we used plastic PVC - rated at 600PSI - for our air lines so we could add lines as needed. At 600 Psi we will never reach the max as we run 100 psi on any given day. Knock on wood never a problem.
....David
| | | | | Joined: Dec 2011 Posts: 241 'Bolter | | 'Bolter Joined: Dec 2011 Posts: 241 | Thanks guys, I would think the money I would save doing some blasting and painting myself would pay for the equipment purchase....at least thats what I will tell her....  I am an electrician and yes to get 3 phase to my shop would be way to costly. Thanks for the advise guys....I had tried the search bar to the left of the screen with not much luck. I just realized there was a search bar up top which I tried and found all kinds of info. Still feeling my way around this site and appreciate your patience. By the way, when you use PVC do you use a solvent to connect fittings or that push fit system? Mark
Last edited by 52_Ton; 02/14/2012 10:23 PM.
| | | | | Joined: Aug 2005 Posts: 6,377 Ex Hall Monitor | | Ex Hall Monitor Joined: Aug 2005 Posts: 6,377 | I've read some horror stories about PVC failing. I know a couple of shops that used PEX to plumb their compressed air with good success so far. I used 1/2" black iron pipe. Worth Reading
Last edited by Tiny; 02/15/2012 1:29 AM.
Save a life, adopt a senior shelter pet. The three main causes of blindness: Cataracts, Politics, Religion. Name your dog Naked so you can walk Naked in the park.
| | | | | Joined: Aug 2010 Posts: 775 'Bolter | | 'Bolter Joined: Aug 2010 Posts: 775 | I bought a "PUMA" 240V 3hp running 6hp rated. Puts out 12CFM at 90PSI. It works great for painting barely will operate a 90lb Harbor Freight sand blaster. You have to use the smallest tip. Also run the sand through a screen or small pieces will plug the nozzel. I have done my whole project frame, cab, etc using this. It's slow and cumberson. You need probably twice this CFM at 90PSI to have a good sand blast experience. | | | | | Joined: Oct 2010 Posts: 171 Wrench Fetcher | | Wrench Fetcher Joined: Oct 2010 Posts: 171 | By the way, when you use PVC do you use a solvent to connect fittings or that push fit system?
Mark Solvent, there are 2 type thin and thick wall-use the thick it's rated over 600 psi
....David
| | | | | Joined: Apr 2005 Posts: 1,971 'Bolter | | 'Bolter Joined: Apr 2005 Posts: 1,971 | Think about what will happen when PVC bursts. It will shatter and fragment. PEX will burst and stay together. For information on compressors, here is one dealer that gives advice on compressors. Look at some of the descriptions on his compressors. http://www.eatoncompressor.com/catalog/item/504747/172983.htm | | | | | Joined: Aug 2011 Posts: 835 Shop Shark | | Shop Shark Joined: Aug 2011 Posts: 835 | Just as another point of reference, I ran 3/4 inch copper for my airlines. It's pricy, but I already had some laying around, and it sure is easy to cut and solder together.
Looks sharp too.
Kurt | | | | | Joined: Jul 2007 Posts: 328 'Bolter | | 'Bolter Joined: Jul 2007 Posts: 328 | I bought the Ingersoll-Rand 60 Gallon twin cylinder machine. Bolted to the floor. I was in the middle of body work on the 51 panel ...... when ....
It threw a rod one month AFTER the warranty ran out ( hardly used in that time).
The good news is that a guy from Ingersoll-Rand CAME TO THE HOUSE! Looked at the block and the bad rod and declared it was a badly cast rod. They charged me only for the house call, he completely replaced the compressor unit on site, tested it, & re-set the warranty to new!
Great customer service. A lot to be said for that ...... | | | | | Joined: Dec 2011 Posts: 241 'Bolter | | 'Bolter Joined: Dec 2011 Posts: 241 | What type of copper did you use. I would be worried about splitting it open with to much pressure. Just as another point of reference, I ran 3/4 inch copper for my airlines. It's pricy, but I already had some laying around, and it sure is easy to cut and solder together.
Looks sharp too.
Kurt | | | | | Joined: Mar 2011 Posts: 229 Shop Shark | | Shop Shark Joined: Mar 2011 Posts: 229 | please read my post in the toolbox before buying an IR air compressor "new air compressor bought wrong brand" before buying your compressor. although now that its up and running it has worked very well even with the blast cabinet.
MO's 1951 chevy 3100 resto mod project
| | | | | Joined: Aug 2011 Posts: 835 Shop Shark | | Shop Shark Joined: Aug 2011 Posts: 835 | I used type K, which is the thicker wall. Here is an excerpt from the "Copper Tube Handbook" with a table of pressures. Rated Internal Working Pressures for Copper Tube: Type K I think you will see that the working pressure is higher than you are likely to use. Kurt | | | | | Joined: Jun 2011 Posts: 1,901 Shop Shark | | Shop Shark Joined: Jun 2011 Posts: 1,901 | I used type K, which is the thicker wall.
I think you will see that the working pressure is higher than you are likely to use.
Kurt Leaving price differences out of it for the moment... I read on that chart the 1/2" is rated 291 lbs higher than the schedule 40 PVC which is only rated at 600 psi. Which will fail first at 120 psi? How long (approx) would it take for the PVC to fail?
Give me ambiguity or give me something else
| | | | | Joined: Aug 2011 Posts: 835 Shop Shark | | Shop Shark Joined: Aug 2011 Posts: 835 | I think the point is that if the PVC fails, it will fail explosively. It will throw out shards that can injure you. If copper fails, it will either split, or a joint will pop loose, but no missiles. A hitch in the day, but not fatal.
Kurt | | | | | Joined: Aug 2005 Posts: 6,377 Ex Hall Monitor | | Ex Hall Monitor Joined: Aug 2005 Posts: 6,377 | I've also read that the oils in a compressed air line can soften PVC and cause failure. That was the deciding factor in me using black iron piping for my runs.
Save a life, adopt a senior shelter pet. The three main causes of blindness: Cataracts, Politics, Religion. Name your dog Naked so you can walk Naked in the park.
| | | | | Joined: Oct 2009 Posts: 201 Shop Shark | | Shop Shark Joined: Oct 2009 Posts: 201 | I wouldn't have thought PVC would fail that way. Clearly it does. http://www.osha.gov/dts/hib/hib_data/hib19880520.htmlHow about black iron or galvanized pipe? Less $ than copper, easy to make up with fittings from Home Depot/Lowes etc.
'69 1/2T stepside, Sea Foam Green, 250 L6 w/ 3 on the tree, not an option on it, in the family since new.
| | | | | Joined: Aug 2011 Posts: 835 Shop Shark | | Shop Shark Joined: Aug 2011 Posts: 835 | Sure, Iron pipe will work very well.
Kurt
| | | | | Joined: Dec 2011 Posts: 241 'Bolter | | 'Bolter Joined: Dec 2011 Posts: 241 | Thanks for all the advice guys. I am going to do some more looking around for the compressor and think when the time comes I will use the black pipe to install the lines. I have been looking through some used equipment sites and have found all different types out here. The only thing that worries me about buying to old is now I would have 2 restoration projects....parts could be an issue. | | | | | Joined: Aug 2008 Posts: 403 Shop Shark | | Shop Shark Joined: Aug 2008 Posts: 403 | There is a company caled RapidAir that you need to take a look at for your air line use. The good thing about it it is cheap and you do not need a pipe threader or pipe wrenches to install the system. and Zero Rust problems. 62Blue Don
62Blue 62Chevy in progress You've never been lost until you've been lost at Mach3" Paul F Crichmore (Test Pilot)