The Stovebolt.com Forums Home | Tech Tips | Gallery | FAQ | Events | Features | Search
9 - 11 Memorials

Searching the Site - a click away
click here to search
New here ??? Where to start?
Click on image for the lowdown. Where do I go around here?
====
Who's Online Now
2 members (Bill Hanlon, Bwana-Jim), 102 guests, and 2 robots.
Key: Admin, Global Mod, Mod
Forum Statistics
Forums66
Topics128,042
Posts1,055,515
Members48,424
Most Online14,466
Apr 26th, 2026
Step-by-step instructions for pictures in the forums
Brad Allen's photos

AD Chevy Trucks

Pictures galore
Over 6,000 pictures

Brad Allen has an awesome collection of Chevrolet factory pictures that he has set up from film strips.

Check them out!

Lots of work on Brad's part ... pure enjoyment (and references) for you!

Big Thanks!

THANKS!

For helping keep this great
old truck web site
on the Internet for

over 30 years!

and not clogged down
with Ads!


Again, thanks!

Previous Thread
Next Thread
Print Thread
Joined: Feb 2000
Posts: 177
K
Kip
Offline
'Bolter
'Bolter
K Offline
Joined: Feb 2000
Posts: 177
I put the generator in a vise, hook up a volt meter to the "A" marked bolt connection on the generator (I'm guessin thats the Generator connection to the voltage regulator on the truck) and the other volt meter lead to Ground on the generator, and spin the generator with a drill.

Anybody done this before? If you have what voltage did your meter read?

Tia and Adios, Kip


Write On The Cross At The Head Of My Grave
To Whiskey And Women Here Lies A Poor Slave

Joined: Feb 2000
Posts: 177
K
Kip
Offline
'Bolter
'Bolter
K Offline
Joined: Feb 2000
Posts: 177
Ok then, How do I bench test a generator?

Tia and Adios, Kip


Write On The Cross At The Head Of My Grave
To Whiskey And Women Here Lies A Poor Slave

Joined: Feb 2002
Posts: 12,029
F
Cruising in the Passing Lane
Cruising in the Passing Lane
F Offline
Joined: Feb 2002
Posts: 12,029
when the local shop has done it for me they put it on a test fixture that drives it with an electric motor and has a couple meters attached ... not sure exactly what's required, but maybe you have an auto electric place around that could check it if ya ask real nice? ohwell

Bill


Moved over to the Passing Lane

"When we tug a single thing in nature, we find it attached to the rest of the world" ~ John Muir
"When we tug a single thing on an old truck, we find it falls off" ~ me
Some TF series details & TF heater pics
Joined: Mar 2002
Posts: 9,115
'Bolter
'Bolter
Joined: Mar 2002
Posts: 9,115
The most basic test is to ground the field and apply a good healthy 6v supply to the armature. If it turns like a motor then it is in working condition. I also turned mine with an electric motor and belt. With the field grounded and no load applied it produced 20 v. You don't want to hold it there very long.


1951 GMC 1 Ton Flatbed -- It is finally on the road and what a great time I have driving it!
1951 1 Ton Completed


My Chevy Master 4 Door is on the Road!
Joined: Feb 2000
Posts: 177
K
Kip
Offline
'Bolter
'Bolter
K Offline
Joined: Feb 2000
Posts: 177
Thanks Guys!

Adios, Kip


Write On The Cross At The Head Of My Grave
To Whiskey And Women Here Lies A Poor Slave

Joined: Feb 2000
Posts: 177
K
Kip
Offline
'Bolter
'Bolter
K Offline
Joined: Feb 2000
Posts: 177
Ok Truckernix, I'm going to hook up my 6 Volt battery charger as the source for "the basic" test you described above and see what happends.

Tia and Adios, Kip


Write On The Cross At The Head Of My Grave
To Whiskey And Women Here Lies A Poor Slave

Joined: Feb 2000
Posts: 177
K
Kip
Offline
'Bolter
'Bolter
K Offline
Joined: Feb 2000
Posts: 177
Originally Posted by truckernix
The most basic test is to ground the field and apply a good healthy 6v supply to the armature. If it turns like a motor then it is in working condition. I also turned mine with an electric motor and belt. With the field grounded and no load applied it produced 20 v. You don't want to hold it there very long.

Ok I did the "basic test" and both generators I have turned good.

BUT spinning the armature with a drill as per the 2nd test you mentioned is only giving me about .25 Volts out (yes the meter is on the right scale) on both of the generators. Is the drill spinning the armature fast enough (3Amp Approx. 1200 RPM drill)?
What am I doing wrong???

Thanks Truckernix!


Adios, Kip




Write On The Cross At The Head Of My Grave
To Whiskey And Women Here Lies A Poor Slave

Joined: Mar 2002
Posts: 9,115
'Bolter
'Bolter
Joined: Mar 2002
Posts: 9,115
Kip,
did you ground the field when you did the spin test? That is really the only way it will produce anything.


1951 GMC 1 Ton Flatbed -- It is finally on the road and what a great time I have driving it!
1951 1 Ton Completed


My Chevy Master 4 Door is on the Road!
Joined: Dec 2007
Posts: 1,403
J
jdl Offline
'Bolter
'Bolter
J Offline
Joined: Dec 2007
Posts: 1,403
Not sure if this applies here but if you turn the generator into a motor might it need repolarized to be a generator again, at least efficiently? If not, it might help anyway.....smile


Jordan D. Long

1954 Chevrolet 3100 1/2-Ton

And some more pictures
Photobucket

I got a 'Possum Pickup... Now I'm the Roadkill King!!! Anyone want to make some Stovebolt Stew?
Joined: Feb 2000
Posts: 177
K
Kip
Offline
'Bolter
'Bolter
K Offline
Joined: Feb 2000
Posts: 177
Go back after it again sometime today. Will post later. Looks like a busy weekend.

Thanks Guys!

Kip


Write On The Cross At The Head Of My Grave
To Whiskey And Women Here Lies A Poor Slave

Joined: Feb 2000
Posts: 177
K
Kip
Offline
'Bolter
'Bolter
K Offline
Joined: Feb 2000
Posts: 177
Ok, One of the generators gives me about 9 Volts out, the other about 1 Volt out. Doin the 2nd test Truckernix explained. I know Not to spin it too long.

Am I getting there?

Tia and Adios, Kip


Write On The Cross At The Head Of My Grave
To Whiskey And Women Here Lies A Poor Slave

Joined: Mar 2002
Posts: 9,115
'Bolter
'Bolter
Joined: Mar 2002
Posts: 9,115
I would think that a generator that will motor should produce a lot more than 9 volts when spun up, with the field connect to ground. Are these Chevy generators? Ford uses a different setup.


1951 GMC 1 Ton Flatbed -- It is finally on the road and what a great time I have driving it!
1951 1 Ton Completed


My Chevy Master 4 Door is on the Road!
Joined: Feb 2000
Posts: 177
K
Kip
Offline
'Bolter
'Bolter
K Offline
Joined: Feb 2000
Posts: 177
Yep they are Delcos.
One has the brushes build into the end cover and is really long.
The other is real short and has the brushes built into the generator housing.
They both have the little metal Delco tag.

I've been grounding the field connection. I'll try one more time.

Should I apply some sort of voltage somewhere to induce (excite) some sort of field first?


Thanks Truckernix!


Adios, Kip


Write On The Cross At The Head Of My Grave
To Whiskey And Women Here Lies A Poor Slave

Joined: Feb 2000
Posts: 177
K
Kip
Offline
'Bolter
'Bolter
K Offline
Joined: Feb 2000
Posts: 177
Hey Truckernix, I got soccer all weekend but will try tackling the generator again in between.

Last night I did try and get better than 8/9 Volts out of the generator but no. And yes I've done Exactly what you told me With Good connections to everything. Also I searched the net till 2AM things like: "spinning AC Delco-Remy 6 Volt generators with a drill output voltage", HA! I found kind of a result a few times. But they were basically Asking the question about how it's done And what the output voltage on the meter should be, No answers though just long explainations on other tests and the motoring one. So I'm still going with your approx. 20.

And Truckernics Thank You VERY Much for helping me with this! I always knew you were a cool cookie.


Adios, Kip


Write On The Cross At The Head Of My Grave
To Whiskey And Women Here Lies A Poor Slave

Joined: Mar 2002
Posts: 9,115
'Bolter
'Bolter
Joined: Mar 2002
Posts: 9,115
Kip,
when I was playing with my generator, I decided to hook it up to a load. I hooked it up to a six volt headlight. With the grounded field and driving it with an electric motor, the headlight went brilliant white and went off like a flash bulb!


1951 GMC 1 Ton Flatbed -- It is finally on the road and what a great time I have driving it!
1951 1 Ton Completed


My Chevy Master 4 Door is on the Road!
Joined: Feb 2000
Posts: 177
K
Kip
Offline
'Bolter
'Bolter
K Offline
Joined: Feb 2000
Posts: 177
Ok I went to an Auto Electric Shop this morning with the Voltage Regulator and Generator off the truck. The guy there said he could only check them on the truck. I explained the two test I have done with the results. He told me it sounds like the Generator is good and that I am not spinning it fast enough with a drill to get 20 Volts out of it. But if it's "motoring" And I'm getting 8-9 Volts out of it with a 1200 RPM drill applied directly to the armature shaft that the generator is good.

I don't know I still need to check the Voltage Regulator. Maybe I'll put everything Back on the truck and test it from there Or try and find another guy who can test the Regulator off the truck.

On top of all this I have regular life to deal with just like everybody else.


Adios, Kip


Write On The Cross At The Head Of My Grave
To Whiskey And Women Here Lies A Poor Slave


Moderated by  Jon G, Rusty Rod 

Link Copied to Clipboard
Home | FAQ | Gallery | Tech Tips | Events | Features | Search | Hoo-Ya Shop
Powered by UBB.threads™ PHP Forum Software 8.0.0