I want to install a battery kill switch in my 52’ chevy 1/2 ton, and I was looking on flea bay and I noticed that the cheaper ones were only rated for 20 amps continuous use, 125 amp surge. With a 63 amp 12 volt alternator, that rating seems to be a bit low. The next step up is 175-200 amp continuous and 1000 amp surge and that seem a bit of overkill.
Your opinions?
Phil Moderator, The Engine Shop, Interiors and Project Journals
1952 Chevrolet 3100, Three on the Tree, 4:11 torque tube Updated to: ‘59 235 w/hydraulic lifters, 12v w/alternator, HEI, PCV and Power front Disc Brakes Project Journals Stovebolt Gallery Forum
Phak, I used an automotive latching solenoid, not only is it a battery kill switch but it will act as an anti theft device. It actuates by a momentary switch hidden in only a place you know about, its sole purpose is to interupt the entire battery voltage so it is either all on or all off. Rated to 125 amp so it will start your truck no problemo. This is a 12 volt model, they have 6 as well.
1953 Chevrolet 3100 261 cu inch, sm420, 3.55 rear, torque tube still,omaha orange, still 6 volt, RPO green glass, side carrier spare, all done In the DITY Gallery Video of the 261 running
1964 GMC 1000 305 Big Block V6, sm420, the next cab off restoration
As sstoke stated, it not the alternator output one needs to be concerned with. It’s the starter current one needs to build to. Bigger (more amp capacity) is better. I have somewhat the same setup as sstroke. I used a silver contacts golf cart solenoid.