Click on image for the lowdown. 
====
| | | Forums66 Topics128,030 Posts1,055,424 Members48,422 | | Most Online14,466 Apr 26th, 2026 | | AD Chevy Trucks Over 6,000 pictures Brad Allen has an awesome collection of Chevrolet factory pictures that he has set up from film strips. Check them out!
Lots of work on Brad's part ... pure enjoyment (and references) for you!
| | THANKS!
For helping keep this great
old truck web site
on the Internet for over 30 years! and not clogged down with Ads! Again, thanks! | | | | Joined: Aug 2006 Posts: 486 'Bolter | | 'Bolter Joined: Aug 2006 Posts: 486 | I found the problem. I should have mentioned in my original post that I'm using solid wire and I had already checked the polarity to the manual. I was not able to verify that gas was flowing because I'm running off a generator and I couldn't hear well enough. After thinking about it last night I decided that I could put the end of the nozzle in a cup of water and look for bubbles. I did that this afternoon and there were no bubbles. I started checking for problems and eventually found that the cable was not plugged completely into the front of the welder. It looked and felt like it was all the way in but looking inside the cover I could see that there was room for it to go in about another 1/16". Apparently the holes were not lining up correctly for gas to get into the cable. I pushed a little harder to get it completely in and checked it again and had gas flowing. It now works just like my old welder. Thanks for all the suggestions.
'64 swb stepside (gone) '57 1 ton '53 phone truck '59 swb '46 1 1/2 ton '68 swb gmc
| | |
| |
| |