on the Internet for over 30 years! and not clogged down with Ads! Again, thanks! | | | | Joined: Oct 2012 Posts: 77 'Bolter | | 'Bolter Joined: Oct 2012 Posts: 77 | Hello all, Got a head scratcher here. My battery is new, as is the voltage regulator, and generator's just been rebuilt by a pro I trust. I took pictures before taking things apart to make sure I put things back together correctly. After everything was back in, I polarized the generator in the prescribed manner. All seemed fine. A few days later, I came out work on a broken rear light, only to discover the new battery completely dead at 0.0 volts. I had an extra battery, so I put it in. The negative terminal sparked hard when I attached it, and with the engine not started and no key in, the Gen light is on bright. All other circuits seem fine, no smoke anywhere (thank goodness). Of course I disconnected the battery again. Advice? Answers? Ridicule? All will be accepted. Thanks.
Greenman Wood '61 Apache 10, 235.
"The duty of a patriot is to protect his country from its government." - Thomas Paine
| | | | | Joined: Feb 2004 Posts: 29,751 Kettle Custodian (pot stirrer) | | Kettle Custodian (pot stirrer) Joined: Feb 2004 Posts: 29,751 | Your new regulator has a stuck cutout relay. Take the cover off the regulator and look at the contacts behind the Bat. terminal. They should be open. If they're stuck closed the battery will discharge itself through the generator. This usually ruins the regulator, and sometimes the generator as well. I'll bet nobody checked the regulator for proper adjustment after it was installed. On a 12 volt system the cutout relay should close as the armature voltage goes above 12.5 volts. It should open anytime the generator voltage goes below battery voltage. Some cutout relays stick or fail to open at the proper time as the engine is shut down, even on a brand new "Made in China" regulator! Jerry
"It is better to be silent and be thought a fool than to speak and eliminate all doubt!" - Abraham Lincoln Cringe and wail in fear, Eloi- - - - -we Morlocks are on the hunt! There is nothing noble in being superior to your fellow man; true nobility is being superior to your former self. - Ernest Hemingway Love your enemies and drive 'em nuts!
| | | | | Joined: Jan 2008 Posts: 4,961 'Bolter | | 'Bolter Joined: Jan 2008 Posts: 4,961 | Although Chinese junk is probably more prone to sticking than OEM, it occasionally happened 50 years ago. I'm sure your regulator is ruined and the generator tried to motor and couldn't so it got hot. I have even seen wire harnesses burn in a situation like this. I always check the Gen wire at the generator for voltage when I install a new regulator, but it can happen with a regulator that has been in service for a while. I recently had it happen on my 64 Farmall with a Delco regulator that had been in service quite a while. I haven't gotten around to figure out what all got hot and I'm not looking forward to finding out. | | | | | Joined: Oct 2012 Posts: 77 'Bolter | | 'Bolter Joined: Oct 2012 Posts: 77 | Thanks, now I know what I'm doing as soon as the sun comes up... Will let you know how it turns out.
"The duty of a patriot is to protect his country from its government." - Thomas Paine
| | | | | Joined: Nov 2007 Posts: 190 Shop Shark | | Shop Shark Joined: Nov 2007 Posts: 190 | Here are some steps to take. 1. Check battery water and general battery condition to see if it will take and hold a charge....Load testing may be necessary. 2. Check wiring for damage and make sure all connections at generator, regulator and battery are tight and free of corrosion. 3. Make sure fan belt is tight enough to drive generator at full capacity. 4. Run engine at medium speed. Using a wire, touch one end to regulator base and other end to a good ground. If this corrects trouble, regulator is not properly grounded anymore. 5. If test 4 does not correct trouble, make this test. Connect a wire from regulator terminal marked "ARM" or "GEN" to regulator terminal marked "BAT" with engine running at medium speed. If charging rate increases, replace old regulator. 6. If test 5 does not correct trouble, make this test. Connect a wire from "FLD" Terminal of regulator to a good ground with engine running at medium speed. If Charging rate increases, replace old regulator.
If none of the above test show a bad regulator then there is probably a problem in the generator itself.
There are basically two regulators supplied, they either come fron India and will usually have green writing on top of them or the "Made in the USA" regulator. Use the Made in US regulator or NOS Delco. The aftermarket made in US is expensive but well worth it. Made in India regs are JUNK and I wont sale them period. If you buy a non-made in US and pay a premium price your getting ripped....The made in US regs have it stamped into the mounting base. | | |
| |
| |