Click on image for the lowdown. 
====
| | | Forums66 Topics128,014 Posts1,055,332 Members48,419 | | Most Online14,466 Apr 26th, 2026 | | AD Chevy Trucks Over 6,000 pictures Brad Allen has an awesome collection of Chevrolet factory pictures that he has set up from film strips. Check them out!
Lots of work on Brad's part ... pure enjoyment (and references) for you!
| | THANKS!
For helping keep this great
old truck web site
on the Internet for over 30 years! and not clogged down with Ads! Again, thanks! | | | | Joined: Sep 2011 Posts: 39 New Guy | | New Guy Joined: Sep 2011 Posts: 39 | I ran my '51 3100, with a '53 235, for about 15 minutes and the generator got very hot to the point thr paint was buring/smoking off. I just had the generator rebuilt. They said it was a 12V and gave me a new 12v regulator to go with it. This was a generator/starter reputable repair shop and they do many cars. Any ideas what would cause the overheating. | | | | | Joined: Aug 2010 Posts: 255 'Bolter | | 'Bolter Joined: Aug 2010 Posts: 255 | I would be callin' that repair shop pronto. | | | | | Joined: May 2012 Posts: 574 'Bolter | | 'Bolter Joined: May 2012 Posts: 574 | did you/they oil it? i would check that out first
1949 Dodge Coronet 1955 2nd Chevy 4400 1.5 ton 1955 2nd Chevy 3100 1/2 ton 1955 2nd Chevy 3100 1/2 ton 1957 Chevy 5400 LCF 2 ton 1966 Dodge D100 Sweptline 1968 Chevy P20 stepvan 1969 GMC LWB pickup 1972 GMC Sprint 1974 CP30 shorty bus There are three things that I've learned never discuss with people: religion, politics, and the Great Pumpkin.----Linus Van Pelt Trying to understand the behavior of some people is like trying to smell the color 9 | | | | | Joined: Sep 2001 Posts: 29,269 Bubba - Curmudgeon | | Bubba - Curmudgeon Joined: Sep 2001 Posts: 29,269 | I once had a bad, new, voltage regulator run the generator so hot that the solder at the windings melted. As described here. | | | | | Joined: Oct 2010 Posts: 1,232 'Bolter | | 'Bolter Joined: Oct 2010 Posts: 1,232 | Here's where the hot solder goes when it's slung off of the armature ... < TWIN SOLDER TRAIL >
- Lonnie My '54 3104Photos that I have shared on Stovebolt via PhotoBucket are no longer available. Please contact me if you want a photo from an old post. lonniecook [at] aol [dot] com. I sold my '54 3104 12/12/2017, but I still visit Stovebolt. OLD STUFF ... houses, furniture, cars, wine ... I love it all | | | | | Joined: Nov 2007 Posts: 190 Shop Shark | | Shop Shark Joined: Nov 2007 Posts: 190 | If its getting hot enough to burn paint off then its way overcharging. Only one thing can cause it to overcharge, the regulator. There are two different regulators available now, If you purchased one that was made in India it will have it on the regulator cover...they are junk. If you have a made in USA brand it will be stamped into the metal. Take a look at which one you have, if its the India one its possible it could be bad from the start. I have never had any issues with the made in USA ones. Take a look at the picture Lonnie posted and look inside of your generator to see if any solder was slung out of the pins. If they did supply you with a faulty regulator and it damaged the generator then they should make it all good. | | | | | Joined: Sep 2011 Posts: 39 New Guy | | New Guy Joined: Sep 2011 Posts: 39 | Kennetw-you mention that the generator is most likely overcharging, but when I checked the battery, after the 15 minutes of running, it was at 8-9 volts and would not crank the engine over. I started with the battery fully charged. I called he generator shop and they said to bring in the generator and regulator. I have not had a chance to see where the regulator was manufacturerd but will do so when I pull out both items. | | | | | Joined: Nov 2007 Posts: 190 Shop Shark | | Shop Shark Joined: Nov 2007 Posts: 190 | ok, so how is your battery? Take it with you and have them charge it again and put it on a load tester. The regulator controls the generator but if the battery has issues and not holding a charge then the generator could be charging to much. The generator is not made to constantly charge at full capacity on a continuous basis and you will get the same effect of a generator over charging. Something is going to eventually give and nine times out of ten the solder in the armature pins is going to be the first to go. | | | | | Joined: Sep 2011 Posts: 39 New Guy | | New Guy Joined: Sep 2011 Posts: 39 | I brought my generator, regulator and battery to the repair shop that did the rebuild. They did a load test on the battery, which checked out fine. They bench tested the generator which was working properly. It turns out the regulator was stuck on and caused the generator to overheat. I had the rebuild done 10 months ago, but the warranty was only for 6 months. Despite the fact that I have only run the truck for 15 minutes in the last 10 months, it did not matter for the warranty, I had to buy a new one(at cost). The regulator did not have a manufacturer name on it, but it did have "Made in USA" stamped on it. I am concerned about the soldier, but the truck seems to running properly, at this point. Thanks to everyone for sharing your knowledge and suggestions. | | | | | Joined: Mar 2002 Posts: 9,115 'Bolter | | 'Bolter Joined: Mar 2002 Posts: 9,115 | Regarding the regulator, I am guessing that the cover was made on the USA! | | |
| |