on the Internet for over 30 years! and not clogged down with Ads! Again, thanks! | | | | Joined: May 2006 Posts: 92 Shop Shark | | Shop Shark Joined: May 2006 Posts: 92 | I have a 48 Chevy 1/2 ton. The generator seems to working right and puts out the correct voltage. It is really hot though, can hardly put your hand on it......Is this a sign of failure? | | | | | Joined: Jan 2006 Posts: 586 Shop Shark | | Shop Shark Joined: Jan 2006 Posts: 586 | If your battery load tests ok and no noise from the generator ( ie bearings), I would not worry about it. I have seen a battery that's on it's way out put a heavy load on a genny.
Wanted Good Woman: Must be able to cook , clean , sew , tune engines and polish trucks. Must have old Stovebolt and garage. Please send picture of old Stovebolt and garage.
| | | | | Joined: Jul 2004 Posts: 5,708 'Bolter | | 'Bolter Joined: Jul 2004 Posts: 5,708 | weltertm,
I agree with gtow69 up to a point. If the output voltage is OK and there is no noise one would think it was fine...but I don't think it should be anywhere near that hot!
The very least I would do is take it off and disassemble it for a look-see. It's pretty easy to do and you might save it before it wipes out the field coils and becomes junk.
What does your ammeter tell you? It shouldn't show a constant, heavy charge. That is not OK. If all is well in the electrical end of things, my bet is a bearing or bushing that is toast but hasn't screamed yet! They don't always make noise.
Stuart | | | | | Joined: Jul 2007 Posts: 461 Shop Shark | | Shop Shark Joined: Jul 2007 Posts: 461 | I think you should have the generator checked, especially if you have low current output. The typical output is about 35 amps, which usually doesn't heat the housing as you describe. There will be a high internal current in the armature if it has a shorted winding. Shorted armatures don't make noise like alternator stators do.
Harvester | | | | | Joined: Jan 2008 Posts: 4,960 'Bolter | | 'Bolter Joined: Jan 2008 Posts: 4,960 | Where is it hot? It has an oil cup at both ends that need oiling every so often. A few drops when it is not running. If it is hot all over after running a while, it may just be because it is working, it has hot air blown over it by the fan, it is attached to a hot engine, and it is situated under the exhaust manifold. | | |
| |
| |