First, do a polarizing procedure. With a short jumper lead, connect the Bat. terminal of the regulator to the Arm. terminal for a short time, less than one second. You should get a pretty good flash. This magnetizes the soft iron pole shoes of the generator field coils, and they retain enough "residual magnetism" to begin the charging process.
Start the engine and run it at a fast idle. The Armature terminal at the generator should develop about 1 volt more than the battery had before starting, minimum. It could be considerably higher, depending on the state of charge of the battery. Regulated voltage against a fully-charged batery will be 14.5 volts or slightly higher, while a very low battery will accept a charge at 13 volts or so.
Be sure the generator housing and the regulator base share a common ground. I usually run a dedicated ground wire to both units, tied into the harness with the armature and field wires. Also, be sure the battery is grounded to the engine in some way, either with a braided ground strap, or a minimum of a #10 wire from the battery ground post to the frame. #8 or larger is better for 6 volt systems.
Jerry
Last edited by Hotrod Lincoln; 09/10/2008 5:18 PM.