| |
Labor Day Putting down your wrenches or time for MORE wrenching? 
Plenty of places to share. | | Click on image for the lowdown. 
====
| | |
4 members (Peggy M, tclederman, 2 invisible),
53
guests, and
2
robots. | | Key: Admin,
Global Mod,
Mod | | | Forums66 Topics128,009 Posts1,055,296 Members48,419 | | Most Online14,466 Apr 26th, 2026 | | AD Chevy Trucks Over 6,000 pictures Brad Allen has an awesome collection of Chevrolet factory pictures that he has set up from film strips. Check them out!
Lots of work on Brad's part ... pure enjoyment (and references) for you!
| | THANKS!
For helping keep this great
old truck web site
on the Internet for over 30 years! and not clogged down with Ads! Again, thanks! | | | | Joined: Apr 2007 Posts: 82 Wrench Fetcher | | Wrench Fetcher Joined: Apr 2007 Posts: 82 | Had my 51 3100 running this weekend and pulled the battery cable off to find out what the issue was causing the dead battery, of course when I pulled the cable off the truck died. I assume then it a generator issue. Do I pull the generator or is there an easy way to test? Rebuild the generator or buy used one from somewhere?
Thanks in advance for your help. | | | | | Joined: Jul 2004 Posts: 5,708 'Bolter | | 'Bolter Joined: Jul 2004 Posts: 5,708 | Purney,
There are two scenarios, one is that the generator is indeed no good, and the other would be that it isn't being told to charge.
I would first polarize your generator. Momentarily touching a wire between BATT and ARM (gen) on regulator will do this. This is done before starting the engine.
Your ammeter, if working should show you what your charging system is doing. If polarizing the regulator makes no difference, you can try a full field test on the generator.
Disconnect the "F" (field) wire at the regulator, and with the truck running, touch it to a good ground. With the RPM's increased, the ammeter should show a hefty charge.
This full field test works best if you have a voltmeter connected somewhere and you can actually see generator output climb to over 7 volts.
So the answer to the question is...the generator could be good and it could be a faulty regulator not telling it to charge. These tests will prove the generator and point the finger at a bum regulator.
Your ammeter should be working....it should alert you to these problems before your battery croaks!
Stuart | | | | | Joined: Sep 2007 Posts: 154 Wrench Fetcher | | Wrench Fetcher Joined: Sep 2007 Posts: 154 | Mr Gabster is right on. Voltage regulators can cause lots of charging issues. Is you battery somthing that will hold a charge ?? Also voltage regulators have/can cause a battery to loose its charge while connected to the system. | | | | | Joined: Apr 2007 Posts: 82 Wrench Fetcher | | Wrench Fetcher Joined: Apr 2007 Posts: 82 | Thanks Stuart, I will give it a try.
Thanks for the feedback west, the battery is brand new and holds a charge until I start up the truck! | | |
| |
| |