The Stovebolt.com Forums Home | Tech Tips | Gallery | FAQ | Events | Features | Search
Help is a click away!

VEHICLE
INFORMATION
KITS


at the

GM Heritage Center
All the details are here.

Searching the Site - a click away
click here to search
New here ??? Where to start?
Click on image for the lowdown. Where do I go around here?
====
Who's Online Now
5 members (Otto Skorzeny, 68ironhead, 32Fordpuchoptop, Guitplayer, greenie-reddy), 56 guests, and 1 robot.
Key: Admin, Global Mod, Mod
Forum Statistics
Forums66
Topics128,090
Posts1,056,016
Members48,430
Most Online14,466
Apr 26th, 2026
Step-by-step instructions for pictures in the forums
Brad Allen's photos

AD Chevy Trucks

Pictures galore
Over 6,000 pictures

Brad Allen has an awesome collection of Chevrolet factory pictures that he has set up from film strips.

Check them out!

Lots of work on Brad's part ... pure enjoyment (and references) for you!

Big Thanks!

THANKS!

For helping keep this great
old truck web site
on the Internet for

over 30 years!

and not clogged down
with Ads!


Again, thanks!

Previous Thread
Next Thread
Print Thread
#1602658 04/27/2026 12:15 PM
Joined: Nov 2021
Posts: 1,372
W
'Bolter
'Bolter
W Offline
Joined: Nov 2021
Posts: 1,372
If this should be in the HP section please feel free to move it.

I have an electric fan and had a problem with my temperature sensor such that the fan did not turn on - the sensor has since been replaced. However, I thought it would be a good idea to have an LED on my dash that would indicate when the fan has power. I spliced the LED into the power wire leading to the fan (after the relay) but the LED is constantly on regardless of the fan running.

Any recommendations on where I need to spice in the LED to indicate when the fan is running (or at least should be running electrically speaking) would be appreciated.


1949/50 3600 Project
Follow in Project Journals
Joined: Feb 2019
Posts: 4,478
AD Addict & Tinkerer
AD Addict & Tinkerer
Joined: Feb 2019
Posts: 4,478
I would think it should be between the temp sensor and the relay, so it’s not exposed to high amperage. Can’t figure why it on all the time.


Phil
Moderator, The Engine Shop, Interiors and Project Journals

1952 Chevrolet 3100, Three on the Tree, 4:11 torque tube
Updated to: ‘59 235 w/hydraulic lifters, 12v w/alternator, HEI, PCV and Power front Disc Brakes
Project Journals
Stovebolt Gallery Forum
Joined: Feb 2000
Posts: 5,212
J
'Bolter
'Bolter
J Offline
Joined: Feb 2000
Posts: 5,212
You should not have any power to the motor when the relay is off, so its odd the LED is lighting up. Add a second smaller relay, that is energized when the main fan relay is energized, that should isolate the LED from any leakage voltage that may be keeping it on.

You should be able to tap right off the positive wire at the relay for the fan, just be sure you are on the output side and not the input, post #87 should be the switched on/off post, #30 is the battery feed, the other two are the switching wire from temp sender and ground.

Joined: Feb 2004
Posts: 29,787
H
Kettle Custodian (pot stirrer)
Kettle Custodian (pot stirrer)
H Offline
Joined: Feb 2004
Posts: 29,787
If the fan has a permanent magnet motor, (most do) if the fan windmills at road speed the motor can probably generate enough voltage to turn the light on. LEDs only require a tiny bit of voltage to operate. You might try wiring the LED to the wire from the sensor that triggers the relay for the motor. Or, you could just use a conventional peanut bulb indicator, not a LED.
Jerry


"It is better to be silent and be thought a fool than to speak and eliminate all doubt!" - Abraham Lincoln
Cringe and wail in fear, Eloi- - - - -we Morlocks are on the hunt!
There is nothing noble in being superior to your fellow man; true nobility is being superior to your former self. - Ernest Hemingway
Love your enemies and drive 'em nuts!
Joined: Nov 2021
Posts: 1,372
W
'Bolter
'Bolter
W Offline
Joined: Nov 2021
Posts: 1,372
Thank you all for the input.

I will try relocating it from the fan positive wire at the relay to the relay temperature sensor wire. Hopefully that does not influence the relay from properly sensing the temperature sensor.


1949/50 3600 Project
Follow in Project Journals
Joined: Nov 2021
Posts: 1,372
W
'Bolter
'Bolter
W Offline
Joined: Nov 2021
Posts: 1,372
Okay, confession time.

I did some more checking and the reason the LED was on was because the relay was wired wrong. The relay was always activated with the power to the fan being controlled directly by the thermo switch. It worked that way but the thermo switch was providing the ground side of the fan power rather than controlling the relay. I suspect that is why my original thermo switch failed (not rated for that type of power).

Now that I have rewired things correctly the relay is controlled by the thermo switch and the fan turns on when the thermo switch triggers the relay to power the fan. The LED is still connected to the power feed to the fan (after the relay) but does not light unless the fan has power (or is moving). When the fan power is removed the LED dims as the fan is slowing and goes out when the fan stops. I suspect that if the fan does windmill due to airflow from the truck moving it may light the LED with the brightness bing an indication of how fast the fan is moving.

I'm glad I decided to add the LED because the confusion it caused resulting in my finding my previous error before I damaged another thermo switch.

I'm sorry that my wiring error resulted in you all needing to try and help me out but once again I appreciate your help confirming that my original intention should have worked if not for my error.


1949/50 3600 Project
Follow in Project Journals
Joined: Feb 2004
Posts: 29,787
H
Kettle Custodian (pot stirrer)
Kettle Custodian (pot stirrer)
H Offline
Joined: Feb 2004
Posts: 29,787
Back in the dark ages, the days of DC generators and 3-unit regulators, there used to be a problem with "no charge" lights glowing faintly, even when the charging system was supposedly working properly. These bulbs were the standard incandescent peanut bulbs, a few decades before LEDs came along. The problem was usually dirty contact points on the cutout relay of the regulator, and the generator would try to find another path to the battery- - - - -through the idiot light! The shade tree fix was to put a higher wattage bulb in the dash to let a little current pass without illuminating the filament as brightly. The correct fix was to clean the cutout points, or replace the regulator.
Jerry


"It is better to be silent and be thought a fool than to speak and eliminate all doubt!" - Abraham Lincoln
Cringe and wail in fear, Eloi- - - - -we Morlocks are on the hunt!
There is nothing noble in being superior to your fellow man; true nobility is being superior to your former self. - Ernest Hemingway
Love your enemies and drive 'em nuts!

Moderated by  Jon G, Rusty Rod 

Link Copied to Clipboard
Home | FAQ | Gallery | Tech Tips | Events | Features | Search | Hoo-Ya Shop
Powered by UBB.threads™ PHP Forum Software 8.0.0