Here's a reference to that model number:

1953 Chevrolet 235 (108 hp) Inline 6 Engine Generator Specs
www.secondchancegarage.com/public/...6-generator-specs.cfm Cached
DELCO-REMY GENERATOR SPECIFICATIONS. Generator Number: 1100018, 1102793 (generator rotates clockwise) Generator output: 1100018 ...

It's listed as "obsolete" by Delco-Remy, not surprising since it's a 1953 6 volt truck item with a 45 amp output by the information I've been able to find. That would make it a heavy-duty unit, as most 6 volt GM generators were either 30 or 35 amp items. To get the full charge current output, most of the regulators available these days would need to have the current regulator adjustment increased by about 10 amps or so. Not difficult- - - -just a spring tension change to the center coil assembly under the regulator cover, but the technician doing the adjusting needs to understand how to load the battery to get a correct current regulator adjustment.
Jerry


"It is better to be silent and be thought a fool than to speak and eliminate all doubt!" - Abraham Lincoln
Cringe and wail in fear, Eloi- - - - -we Morlocks are on the hunt!
There is nothing noble in being superior to your fellow man; true nobility is being superior to your former self. - Ernest Hemingway
Love your enemies and drive 'em nuts!