Joe -

I'm talking outta my ear on this one, so take it with a grain of salt. Other 'Bolters with real experience can give you the correct info.

A low cut-in generator starts charging at a lower speed. More specifically, it starts producing a voltage equal to that of a fully charged battery. The armature is wound to produce current at low RPM's and a second winding to produce current at higher RPM's. The output amperage is lower in order to keep from having to increase the size of the armature and generator case by a large amount.

The voltage regulator is designed and adjusted to match the low cut-in generator.

I don't know if 1100018 and 1100028 are physically different on the outside. The '29-'57 MPC shows the overall length of both is 9-1/2 inches.
> '29-'57 MPC

By the way, Ken Warner "Kennethw" at ClassicGenerator built the generator that is on my truck. He wound it for 12v and matched a regulator to it. They work great and look new. The 12v regulator does not have the screws through the top of the cover. I replaced the blank VR cover with a Delco-Remy cover that I bought on Stovebolt.

- Lonnie


- Lonnie
My '54 3104
Photos that I have shared on Stovebolt via PhotoBucket are no longer available. Please contact me if you want a photo from an old post.
lonniecook [at] aol [dot] com. I sold my '54 3104 12/12/2017, but I still visit Stovebolt.

OLD STUFF ... houses, furniture, cars, wine ... I love it all