Lots of work on Brad's part ... pure enjoyment (and references) for you!
| | THANKS!
For helping keep this great
old truck web site
on the Internet for over 30 years! and not clogged down with Ads! Again, thanks! | |
#85788 04/10/2005 4:06 PM | Joined: Jun 2004 Posts: 8,597 Riding in the Passing Lane | | Riding in the Passing Lane Joined: Jun 2004 Posts: 8,597 | The regulator has 3 terms. There should be a ground wire to the base. There possibly is 2 wires going to the bat. term. Remove the wire to the field term at the regulator & ground it. The generator should show full charge. Do not run it long or very fast this way. If it shows a charge the regulator is bad or defect in the wireing. If no charge the gen. needs rebuilt. They say money can't buy happiness. It can buy old Chevy trucks though. Same thing. 1972 Chevy c10 Cheyenne SuperIn the Gallery Forum | | |
| |
| |