Hy mauricioaglr, no you cannot connect the "yellow" wire to the starter, you actually do not have a solenoid any longer, you have a manually closed switch. Connect the "yellow" wire to the coil positive terminal, that way your alternator will be activated to begin charging when the ignition is activated, this will only work if you are using the DA plug which has a diode built into it to prevent the alternator from backfeeding the ignition circuit. If you wired the "yellow wire to the starter terminal (battery) your alternator would be turned on all the time, and would probably drain the battery, hope that helps.