on the Internet for over 30 years! and not clogged down with Ads! Again, thanks! | | | | Joined: Feb 2004 Posts: 29,772 Kettle Custodian (pot stirrer) | | Kettle Custodian (pot stirrer) Joined: Feb 2004 Posts: 29,772 | The 2-terminal alternator has what's called an "isolated field" system. There is no internal ground for the alternator field coil. It you choose to use the 2-terminal alternator, just ground one of the field terminals (doesn't matter which one) and run the original field wire from your existing regulator to the remaining field terminal.
The factory wiring for the isolated field alternator ran 12 volts to one field terminal, and put the regulator on the ground side. That one takes a different regulator so the simplest way is to create an external ground for the replacement alternator. Jerry
"It is better to be silent and be thought a fool than to speak and eliminate all doubt!" - Abraham Lincoln Cringe and wail in fear, Eloi- - - - -we Morlocks are on the hunt! There is nothing noble in being superior to your fellow man; true nobility is being superior to your former self. - Ernest Hemingway Love your enemies and drive 'em nuts!
| | |
| |
| |