OK, I re-read your original post. Getting 0 volts at the distributor side of the coil- - - -WITH THE POINTS CLOSED- - - - - is normal since the non-moving point is grounded. That's what lets the primary current flow to ground and energize the coil. If you're getting 0 volts at the side terminal of the distributor or the downstream side of the coil with the points open, you have created an unintentional ground at the distributor connector or the moving point during your installation of the new points. Recheck everything you have done recently- - - -it's easy to get the primary circuit grounded between the distributor housing and the points so that opening the points doesn't interrupt the circuit.