I usually ground the F terminal to the generator housing and apply battery voltage to the ARM terminal while the generator is clamped in a vise. Connect the battery ground to the housing, or just clamp the end of a cable under the vise jaw that's holding the generator. Sometimes it's necessary to give the pulley a little spin to get things started. Don't run one long that way (15 seconds or so is plenty), as it can overheat the windings.
Jerry,
Your generator test worked like a charm! It took off on its own and I ran it for 10 seconds or so.
Thanks,