on the Internet for over 30 years! and not clogged down with Ads! Again, thanks! | | | | Joined: Feb 2004 Posts: 29,760 Kettle Custodian (pot stirrer) | | Kettle Custodian (pot stirrer) Joined: Feb 2004 Posts: 29,760 | They're stamped on the terminal lugs of the regulator- - - -BAT- - - -ARM- - - -FLD. "Battery- - - -Armature- - - -Field". The armature wire is usually in the middle. The Field terminal will also have a very small-gauge wire. Battery and Armature wires are noticeably larger gauge. It's also a very good idea to run a dedicated ground wire from the regulator base to the generator housing, if one isn't there already. Jerry
"It is better to be silent and be thought a fool than to speak and eliminate all doubt!" - Abraham Lincoln Cringe and wail in fear, Eloi- - - - -we Morlocks are on the hunt! There is nothing noble in being superior to your fellow man; true nobility is being superior to your former self. - Ernest Hemingway Love your enemies and drive 'em nuts!
| | |
| |
| |