on the Internet for over 30 years! and not clogged down with Ads! Again, thanks! | | | | Joined: Feb 2004 Posts: 29,751 Kettle Custodian (pot stirrer) | | Kettle Custodian (pot stirrer) Joined: Feb 2004 Posts: 29,751 | You should not have gotten more than about 1 volt at the generator armature terminal with the field wire disconnected. Something, possibly internally in the generator, is allowing the field circuit to find a ground. Check the insulator at the "F" stud in the generator to see if it is contacting the housing. The only place you should get a ground for the field circuit is through the regulator points. I would consider 1/8 turn of the regulator adjusting screw to be a HUGE change. Jerry
"It is better to be silent and be thought a fool than to speak and eliminate all doubt!" - Abraham Lincoln Cringe and wail in fear, Eloi- - - - -we Morlocks are on the hunt! There is nothing noble in being superior to your fellow man; true nobility is being superior to your former self. - Ernest Hemingway Love your enemies and drive 'em nuts!
| | |
| |
| |