Originally Posted by Hotrod Lincoln
Close up the gap just a little. "Dwell" indicates the number of degrees of distributor rotation the points "dwell together"- - - -points closed, to make it simple. A 6-lobe distributor cam has 60 degrees between high spots, and the points need to stay closed approximately 2/3 of the time, so 40 degrees would be the maximum points closed time. Early stovebolt distributors ran 37-38 or more, while later models dropped the dwell down to the low 30's for some reason.
Jerry

Think the change was the cam profile changed as per DEVE HEI upgrade how to ID early from late distributors.

http://devestechnet.com/Home/HEIgnition