I have just completed a total ground up resto on my 50 1300. And of course theres always some gremlins etc to fix. I started driving it and amp gauge was always reading in the discharge side. Finally went too start it 2 days ago and battery was flat. Charged it up and started it. Checked voltage at battery and at regulator B terminal both were 6 volts. Not about 8 volts. So I grounded field and got the gauge to read properly and a high 8.5v charging voltage. So I decided too remove this regulator and replace it with the old dirty grungy one and guess what ? It worked perfectly!
Go figure....