on the Internet for over 30 years! and not clogged down with Ads! Again, thanks! | | | | Joined: Dec 2012 Posts: 97 Wrench Fetcher | | Wrench Fetcher Joined: Dec 2012 Posts: 97 | Hi Guys, I have a new switch, at least I thought it was, in my deluxe heater ('59-3spd). It's been working fine. But I switched it on and suddenly I can't move it back to off. It runs at full speed then I can move it slightly to middle speed and that is it. Don't want to force it, but it was working smooth as silk.
Has anyone encountered this? Have not pulled it yet to figure it out. Just looking for clues.
Thanks, Dave | | | | | Joined: Feb 2002 Posts: 12,029 Cruising in the Passing Lane | | Cruising in the Passing Lane Joined: Feb 2002 Posts: 12,029 | "encountered this"? as in something broke?  clue: the repros aren't the greatest quality, all you can do is take it out and see what happened Bill | | | | | Joined: May 2005 Posts: 8,983 Sir Searchalot | | Sir Searchalot Joined: May 2005 Posts: 8,983 | Pop it out of there, hopefully it's machanical problem not internal electrical. Usually electrical is not the "can't move" kind, it will be mechanical lever/link/rivet/screw/bent/broken bracket something. Easy as pie, piece of cake.
Right is right, even if everyone is against it, and wrong is wrong, even if everyone is for it. - William Penn | | | | | Joined: Dec 2012 Posts: 97 Wrench Fetcher | | Wrench Fetcher Joined: Dec 2012 Posts: 97 | Yah, it's coming out.
Major PITA after just putting it in. Suddenly before the switch issue, I also had the fuse blow out after shutting down ignition about three times, then this happened. Motor would run fine in all positions, then not run after a shut down. And now the fuse is not blowing. Will be interesting to see what becomes of this when I get to inspect. I know fuse may or may not be and related, we'll see.
| | | | | Joined: Dec 2012 Posts: 97 Wrench Fetcher | | Wrench Fetcher Joined: Dec 2012 Posts: 97 | Finally got a chance to take the switch out. It was internal, mechanical, fairly simple and easy to fix. Might last a long time now or we'll see. If you have never had one apart, there is a spring inside so pay attention lifting the circuit board cover slowly.
In this case a brass slider/shoe rides over the contacts and it had worn itself to the point of hanging up. Weird because it was very sudden and showed no sign of resistance previously. A small file to smooth/bevel out the contacts and edge of shoe and back together it went.
Have not tested the fuse part yet. Needs a long drive for that.
| | |
| |
| |