Click on image for the lowdown. 
====
| | | Forums66 Topics128,049 Posts1,055,552 Members48,425 | | Most Online14,466 Apr 26th, 2026 | | AD Chevy Trucks Over 6,000 pictures Brad Allen has an awesome collection of Chevrolet factory pictures that he has set up from film strips. Check them out!
Lots of work on Brad's part ... pure enjoyment (and references) for you!
| | THANKS!
For helping keep this great
old truck web site
on the Internet for over 30 years! and not clogged down with Ads! Again, thanks! | | | | Joined: Nov 2006 Posts: 324 Shop Shark | | Shop Shark Joined: Nov 2006 Posts: 324 | I have just started to mock up the 4.3 v/6 engine. I'm planning to install in my 51. Mustang ll IFS is in place. Also planning to use the original rad if possible. After leveling everything in the mockup, It almost looks like the fan is about 2" to low? Planning to fabricate a shroud, trans. & motor mounts. Need advice on the fan height??Sugestions??? | | | | | Joined: Sep 2003 Posts: 1,820 Shop Shark | | Shop Shark Joined: Sep 2003 Posts: 1,820 | While we are on the subject, if using a pusher fan, can anyone recommed how many cfm is enough? Or is it a matter of getting the most you can? In other words, is there a minimum cfm fan one should have to be safe? Not trying to hi-jack the thread, just thought this would be a good spot for some input on this air movement question. By the way, Jim - I have had my pusher set up exactly the way you describe, and it has been successful. Thank you! Joe 
Last edited by 6cylindersovertexas; 12/22/2008 4:04 AM.
"Truckin' Around .......... Since 1937!" My name is Joe and I am addicted to Classic Country Music. I just can't hep myself.Operators are standing by to take your calls! Now cruising in the Passing Lane | | | | | Joined: Jul 2005 Posts: 2,031 Shop Shark | | Shop Shark Joined: Jul 2005 Posts: 2,031 | when I contacted a SPAL distributor/vendor 'the fanman' http://www.the-fan-man.com/shop/siz...?osCsid=3bc69328aed189562027af6f037ce1a3 they said the 2300cfm fan was noisy and he recommanded the 2000cfm that i have in 16'' installed in my rig. whatever blade design,,,,,,, I went for the optimal cfm and their recomendation. the fan has power ALL the time and is ground start off the relays via a switch. it works on 2 relays and a 190 degree napa temp switch that completes the ground circuit to operate the relays at 190 degree water temp. http://s67.photobucket.com/albums/h298/1951otter/?action=view¤t=19A-1-1.jpg ........... see the note and ^^
Last edited by carolines truck; 12/22/2008 6:31 PM.
Jim & Caroline The highway is for gamblers, better use your good sense." Gooday-that's my 1¢ answer due to the lousy economy ~ cause I ain't got - no . mo . doe Every Shaver | Now Can Snore | Six More Minutes | Than Before ... | Half A Pound for Half a Dollar | Spread On Thin | Above the Collar || BURMA-SHAVE
| | | | | Joined: Dec 2000 Posts: 506 Shop Shark | | Shop Shark Joined: Dec 2000 Posts: 506 | Vickraft, Only think i can think of that other have not said is to get a curved blade fan vs strainth. THe curved blades are quieter vs straight.
"Drugs are money, money is power, power is security." - Kent Heiner Nedrow population 2212 Carbon footprint family of 2/11 tonnes of CO2/yr
| | | | | Joined: Nov 2006 Posts: 324 Shop Shark | | Shop Shark Joined: Nov 2006 Posts: 324 | Wow you guys have got me thinking. Thanks, Alan Horvath,Carolina trucks & everyone else for the wealth of information and sites. Originally as a first time builder I had thought if I just re-installed the original mechanical fan that was on the 4.3 and the very thick 51 rad with shroud that it would handle the cooling. Because the fan on the 4.3 is much lower than the original 216 (about 2") and not up high enough I may have to consider a pusher fan.No shroud! (16",quieter 2000cfm with double relay wiring (to share the load)as was very well explained.)good photo's etc. I presume the reason for a pusher fan is that it would not rob power from the engine like the mechanical fan would? Can be installed exactly where it is needed? Increase fuel efficiency? Also perhaps this would allow a little more room because of the removal of the mechanical fan?
Thanks to everyone for your time & consideration. Mery xmas & happy New Year to all. | | | | | Joined: Oct 2006 Posts: 119 Wrench Fetcher | | Wrench Fetcher Joined: Oct 2006 Posts: 119 | As much as I like the guys at Fatman Fabrications, noise of the fan shouldn't be a consideration - that's why Dynamat was invented. I got a Flexalite 180 because it gets pretty hot here in summer and I liked how the built in shroud fit the radiator. If you plan on having a/c remember that your condenser needs to be in front of the radiator so you'll probably need a puller. http://picasaweb.google.com/ChrisAurit/ItSChrisGreenTruck#5282942604883435474 | | | | | Joined: Nov 2006 Posts: 324 Shop Shark | | Shop Shark Joined: Nov 2006 Posts: 324 | Yes, you are right Carolines truck, I should consider photo's with notes with my inquiries. Good references help a lot. Nice pic's & nice truck Desert buick. I had not considered a/c. We only get about 2 weeks a year when its really hot & humid the rest of the time during the summer is comfortable. But a/c would be nice to add on later if I start to travel & visit warmer places. How much space did you end up leaving betwween the shroud/fan & front of the mech. fan pulley?
Planning to take some pic's soon. My cab is now back on the frame. The motor/trans. unit ready to be lowered, once my rad is bolted in front I will start to mock the whole set up. Fabricate motor & trans. mounts. | | | | | Joined: Jul 2005 Posts: 2,031 Shop Shark | | Shop Shark Joined: Jul 2005 Posts: 2,031 | That is ........ f a N m a n ...... not .... fa Tman yes i have dynamat around my cab, see my photos. I listened to what the vendor/dealer said, my truck, areas where i travel and took his recomendations. he could have made a bigger profit if i had bought the 2300+ cfm fan 
Last edited by carolines truck; 12/23/2008 6:30 PM.
Jim & Caroline The highway is for gamblers, better use your good sense." Gooday-that's my 1¢ answer due to the lousy economy ~ cause I ain't got - no . mo . doe Every Shaver | Now Can Snore | Six More Minutes | Than Before ... | Half A Pound for Half a Dollar | Spread On Thin | Above the Collar || BURMA-SHAVE
| | |
| |