The Stovebolt.com Forums Home | Tech Tips | Gallery | FAQ | Events | Features | Search
Help is a click away!

VEHICLE
INFORMATION
KITS


at the

GM Heritage Center
All the details are here.

Searching the Site - a click away
click here to search
New here ??? Where to start?
Click on image for the lowdown. Where do I go around here?
====
Who's Online Now
3 members (stlcardinalsguy, dunfire, Otto Skorzeny), 110 guests, and 1 robot.
Key: Admin, Global Mod, Mod
Forum Statistics
Forums66
Topics128,136
Posts1,056,427
Members48,441
Most Online14,466
Apr 26th, 2026
Step-by-step instructions for pictures in the forums
Brad Allen's photos

AD Chevy Trucks

Pictures galore
Over 6,000 pictures

Brad Allen has an awesome collection of Chevrolet factory pictures that he has set up from film strips.

Check them out!

Lots of work on Brad's part ... pure enjoyment (and references) for you!

Big Thanks!

THANKS!

For helping keep this great
old truck web site
on the Internet for

over 30 years!

and not clogged down
with Ads!


Again, thanks!

Previous Thread
Next Thread
Print Thread
Joined: Sep 2011
Posts: 2,951
L
'Bolter
'Bolter
L Offline
Joined: Sep 2011
Posts: 2,951
I’ve examined every wire for continuity. This AAW wiring kit was installed by me about 5 years ago. There are no wonky connections.
Brake lights and turn signals all work properly. Only the park light fuse blows - repeatedly.
I need to step away and let my mind settle.
What should I do besides test each wire for ohms/continuity?'
When the fuse blows I lose front and rear park/running lights and dash lights. I thought I had a short in the license plate light but it tests ok. With the rear bulbs inserted and grounded I get right around 5 ohms for that rear circuit.
Could it be a bad light switch?

Joined: Jan 2019
Posts: 2,242
Herder of Cats, Goats, and Sheep (moderator)
Herder of Cats, Goats, and Sheep (moderator)
Joined: Jan 2019
Posts: 2,242
Sounds to me like an intermittent short to ground. It tests fine most of the time, but blows the fuse when you hit a bump just the right (wrong) way.

Have you traced the wires to look for wear/pinch points? That is what I would try next.


From the Rocky Mountains?
Check in with the RM Bolters!
HiPo Forum Moderator

1958 Task Force Truck
"Frank" gets a new lease on life
Follow in the DITY Gallery
1959 3200 Task Force
The Ballad of Enkidu
The Saga in the DITY Gallery ~ and the story continues
Joined: Sep 2011
Posts: 2,951
L
'Bolter
'Bolter
L Offline
Joined: Sep 2011
Posts: 2,951
Originally Posted by Fibonachu
Sounds to me like an intermittent short to ground. It tests fine most of the time, but blows the fuse when you hit a bump just the right (wrong) way.

Have you traced the wires to look for wear/pinch points? That is what I would try next.

I agree. Intermittent. Funny thing is that it’s been fine for several years. I suspected my LED license plate light but so far it tests fine and I don’t see any broken wires. I think I even had it out of the circuit once when I blew a fuse, so I sorta ruled it out that way. 10A fuse.

Funny how you can fool yourself sometimes trying to trace short. Thought I was tracking a short as I kept finding continuity to ground as I moved closer to the cab. Then I realized that the front park light bulbs were grounded and I was interpreting that as a short to ground. Haha! Remove bulbs = short went away. I had continuity through the bulb filament and the bulb base was grounded.
Sure tests my abilities but so far I’ve found nothing.

Joined: Jan 2019
Posts: 2,242
Herder of Cats, Goats, and Sheep (moderator)
Herder of Cats, Goats, and Sheep (moderator)
Joined: Jan 2019
Posts: 2,242
I won't admit to having to done the same thing before wink

The usual culprits in my experience are sheet metal penetrations and sockets. If you don't see any obvious wear spots, you might try turning the lights on and wigging the wiring in different places to see if you can cause it.

I had one years ago where the isolation in the socket itself was degrading and it would occasionally short inside. I found it by wiggling the wiring going into the socket.


From the Rocky Mountains?
Check in with the RM Bolters!
HiPo Forum Moderator

1958 Task Force Truck
"Frank" gets a new lease on life
Follow in the DITY Gallery
1959 3200 Task Force
The Ballad of Enkidu
The Saga in the DITY Gallery ~ and the story continues
Joined: Jul 2000
Posts: 2,195
Insomniac
Insomniac
Joined: Jul 2000
Posts: 2,195
Check wires running close to the exhaust. I had an intermittent short. Wire crossing over the exhaust pipe would get longer as the pipe warmed it up. Eventually, it would touch the pipe and out go the lights!


Gord 🇨🇦
----
1954 1/2 ton 235 4 speed
Joined: Feb 2004
Posts: 29,818
H
Kettle Custodian (pot stirrer)
Kettle Custodian (pot stirrer)
H Offline
Joined: Feb 2004
Posts: 29,818
One diaqgnostic tool I use routinely is a self-resetting circuit breaker substituted for the fuse while doing my troubleshooting. It saves a pocketful of money on fuses until the source of the short can be isolated, without the wire melting hazard created by bypassing the fuse, even temporarily. Ditto on looking for chafed insulation anywhere the wires go through a piece of sheet metal. Intermittent shorts can get downright frustrating! Is there a possibility you might be dealing with "not enough fuse"- - - -like maybe a 10 amp fuse where a 15 might be better? I've seen current loads cause repeated fuse failures where the normal current flow is within an amp or so of the current the fuse can carry safely.
Jerry


"It is better to be silent and be thought a fool than to speak and eliminate all doubt!" - Abraham Lincoln
Cringe and wail in fear, Eloi- - - - -we Morlocks are on the hunt!
There is nothing noble in being superior to your fellow man; true nobility is being superior to your former self. - Ernest Hemingway
Love your enemies and drive 'em nuts!
Joined: May 2015
Posts: 11,078
Housekeeping (Moderator) Making a Stovebolt Bed & Paint and Body Shop Forums
Housekeeping (Moderator) Making a Stovebolt Bed & Paint and Body Shop Forums
Joined: May 2015
Posts: 11,078
I assume you've checked the bulbs. If one burns out and the filament holders touch, that's a dead short. Stranger things have happened, and a bad bulb is easy to fix.
I had an instance where my blinkers on my daily driver truck didn't flash on the right side. I was SURE it was the switch and replaced that. Not fixed. I had my camper on so couldn't check the trucks taillight bulbs. Drove from Spokane WA, to Wichita KS manually working the lever for right turns. dang Finally had an opportunity to take the camper off and found the two filaments shorted together, so there wasn't enough current to activate the flasher because of the resistance through the turn signal filament AND the tail light filament. Replacing the bulb fixed it up.


Kevin
1951 Chevy 3100 work truck
Follow this saga in Project Journal
Photos
1929 Ford pickup restored from the ground up. | 1929 Ford Special Coupe (First car)
Busting rust since the mid-60's
If you're smart enough to take it apart, you darn well better be smart enough to put it back together.
Joined: Jan 2000
Posts: 591
D
'Bolter
'Bolter
D Offline
Joined: Jan 2000
Posts: 591
You could try this:

1. Take out he parking light bulbs and see if the fuse still blows
If not, put them in one at a time to localize the fault

2. Disconnect the parking light connections, see if the fuse blows
If not, put them in one at a time to localize the fault

3. I have a 1957 pickup, one time I started to melt wires/fuses. Found out it was the metal wrapping on the speedometer cable contacting the back of the dash panel
and shorting a contact from a dash light to ground. A little obtuse, but something to check if you can't find the culprit.

don

Joined: Sep 2011
Posts: 2,951
L
'Bolter
'Bolter
L Offline
Joined: Sep 2011
Posts: 2,951
Thank you for all the supportive advice. I have not found any obvious short to ground. I am convinced that is the problem, but have not found the culprit. I am most suspicious of my LED license plate light.
At present, everything is working again as it should. if the problem recurs, I will start eliminating components, starting with the license plate light.

Last edited by Lugnutz; 09/26/2023 12:01 PM.
Joined: Dec 2020
Posts: 1,966
G
'Bolter
'Bolter
G Offline
Joined: Dec 2020
Posts: 1,966
Run your LED light straight to the fuse block. The fuse blowing is the small one
in the light switch itself? I ran my license plate light to the block that powers the dash lights.
Also new LED


~ BD.
"You won't find me in an old folks home" Pioneer Florida Cracker
1958 Apache Stepside
1958 Apache 1/2 ton Panel
1959 Apache 1/2 ton Panel

Moderated by  Jon G, Rusty Rod 

Link Copied to Clipboard
Home | FAQ | Gallery | Tech Tips | Events | Features | Search | Hoo-Ya Shop
Powered by UBB.threads™ PHP Forum Software 8.0.0