The Stovebolt.com Forums Home | Tech Tips | Gallery | FAQ | Events | Features | Search
9 - 11 Memorials

Searching the Site - a click away
click here to search
New here ??? Where to start?
Click on image for the lowdown. Where do I go around here?
====
Who's Online Now
4 members (baldeagle, Cosmo, CuzzFuzz, Ponchogl), 66 guests, and 6 robots.
Key: Admin, Global Mod, Mod
Forum Statistics
Forums66
Topics128,021
Posts1,055,346
Members48,420
Most Online14,466
Apr 26th, 2026
Step-by-step instructions for pictures in the forums
Brad Allen's photos

AD Chevy Trucks

Pictures galore
Over 6,000 pictures

Brad Allen has an awesome collection of Chevrolet factory pictures that he has set up from film strips.

Check them out!

Lots of work on Brad's part ... pure enjoyment (and references) for you!

Big Thanks!

THANKS!

For helping keep this great
old truck web site
on the Internet for

over 30 years!

and not clogged down
with Ads!


Again, thanks!

Previous Thread
Next Thread
Print Thread
#1219055 05/28/2017 8:38 PM
Joined: Aug 2014
Posts: 307
S
'Bolter
'Bolter
S Offline
Joined: Aug 2014
Posts: 307
Recently replaced battery cables and now have poor cranking and negative cable gets hot. Starter is new. Battery reads 12v on MM. Bad ground?

scottss60 #1219059 05/28/2017 9:16 PM
Joined: Sep 2001
Posts: 29,269
Bubba - Curmudgeon
Bubba - Curmudgeon
Joined: Sep 2001
Posts: 29,269
If you have a set of jumper cables, try jumping:

- negative on battery to bolt on starter
if that does not help
- positive on battery to positive post on starter
if that dies not work, you might have a bad starter?

foot-actuated starter or electric-solenoid-actuated starter?

scottss60 #1219060 05/28/2017 9:33 PM
Joined: Aug 2014
Posts: 307
S
'Bolter
'Bolter
S Offline
Joined: Aug 2014
Posts: 307
Foot starter. Not in position to jump. Going to clean ground on frame and try.

scottss60 #1219065 05/28/2017 11:50 PM
Joined: Aug 2014
Posts: 307
S
'Bolter
'Bolter
S Offline
Joined: Aug 2014
Posts: 307
Replaced neg cable without any change. Battery always reads charged at but hardly cranks the engine. Will try new battery tomorrow.

scottss60 #1219076 05/29/2017 1:47 AM
Joined: Jan 2013
Posts: 1,384
J
Shop Shark
Shop Shark
J Offline
Joined: Jan 2013
Posts: 1,384
What gauge cables did you use?
6V requires O gauge minimun, OO even better.
If you went with the box store 4 Ga, that's your problem.

Jim Sears #1219111 05/29/2017 8:58 AM
Joined: Sep 2001
Posts: 29,269
Bubba - Curmudgeon
Bubba - Curmudgeon
Joined: Sep 2001
Posts: 29,269
Originally Posted by Jim Sears
What gauge cables did you use?
6V requires O gauge minimun, OO even better.
If you went with the box store 4 Ga, that's your problem.
"Battery reads 12v on MM."

scottss60 #1219135 05/29/2017 2:31 PM
Joined: Jun 2004
Posts: 8,597
W
Riding in the Passing Lane
Riding in the Passing Lane
W Offline
Joined: Jun 2004
Posts: 8,597
Sounds like you got a cheapy cable. Sometimes they look good on the outside but are all plastic with too small of wire. If the ground cable hooks to the engine assembly make sure the connection is clean & tight. If it hooks somewhere else make sure there is a good heavy ground cable to the engine. If the bat is strong & the cables are good you could have a bad starter.


They say money can't buy happiness. It can buy old Chevy trucks though. Same thing.
1972 Chevy c10 Cheyenne Super
In the Gallery Forum
scottss60 #1219181 05/29/2017 7:01 PM
Joined: Jan 2016
Posts: 264
5
'Bolter
'Bolter
5 Offline
Joined: Jan 2016
Posts: 264
OK, you also said that neg cable got hot, did the positive as well? Heat in a cable means one of two things only: the starter drawing to much amperage, or cable is not adequate in some way. Best first check was cable. Was replacement at least 0 as mentioned, and have really good ends? You can run both cables at same time as well. Next is checking out starter. Could try removing and try it with jumpers to a good battery, or take to a parts place or motor shop that can test it.


1952 Chevrolet 1700 Bickle Seagrave
"Old Smokey'"
Following the build in the DITY Gallery
scottss60 #1219205 05/29/2017 9:39 PM
Joined: Aug 2014
Posts: 307
S
'Bolter
'Bolter
S Offline
Joined: Aug 2014
Posts: 307
Replaced neg cable. New battery and fired right up. Previous battery just did not have cranking power despite reading "charged" on the battery tender. Thanks for all advice!

scottss60 #1219206 05/29/2017 9:44 PM
Joined: Aug 2014
Posts: 307
S
'Bolter
'Bolter
S Offline
Joined: Aug 2014
Posts: 307
Also ensured good ground to frame with wire brush.

scottss60 #1219250 05/30/2017 2:53 AM
Joined: Mar 2010
Posts: 10,270
5
Renaissance Man
Renaissance Man
5 Offline
Joined: Mar 2010
Posts: 10,270
I do not like the way GM wired the ground wire to the frame next to the battery, then from the frame to the engine block. Its one too many extra places for rust to occur.
I use a longer ground cable from the battery to the frame where the woven ground strap is which goes to engine.
Carl


1952 5-window - return to "as built" condition | 1950 3100 with a 235 and a T-5 transmission
scottss60 #1219266 05/30/2017 4:16 AM
Joined: Aug 2014
Posts: 307
S
'Bolter
'Bolter
S Offline
Joined: Aug 2014
Posts: 307
It is a 12 volt. Not sure of the gauge of the new cable but will check.

52Carl #1219303 05/30/2017 1:26 PM
Joined: Feb 2004
Posts: 29,746
H
Kettle Custodian (pot stirrer)
Kettle Custodian (pot stirrer)
H Offline
Joined: Feb 2004
Posts: 29,746
Originally Posted by 52Carl
I use a longer ground cable from the battery to the frame where the woven ground strap is which goes to engine.

Wouldn't it be better to attach that long cable directly to the engine, or maybe a bellhousing bolt? Then use a ground strap to the frame and/or the cab to handle such things as grounding the lights, voltage regulator, etc.

Another one between the bed and the frame helps with tail lights, turn signals, and such. There's no such thing as having too many grounds!
Jerry



"It is better to be silent and be thought a fool than to speak and eliminate all doubt!" - Abraham Lincoln
Cringe and wail in fear, Eloi- - - - -we Morlocks are on the hunt!
There is nothing noble in being superior to your fellow man; true nobility is being superior to your former self. - Ernest Hemingway
Love your enemies and drive 'em nuts!
scottss60 #1219312 05/30/2017 2:49 PM
Joined: Sep 2001
Posts: 29,269
Bubba - Curmudgeon
Bubba - Curmudgeon
Joined: Sep 2001
Posts: 29,269
On my 6v Suburban, I have ground straps from the frame to the clutch housing on both sides of the engine. Also, a ground strap from the head to the firewall (GM spec for radio).

And, just to be safe, I run the 00 ground cable from the negative terminal on the battery directly to a starter mounting bolt (instead for the strap/cable from bettery frame.

My only weak grounds are for some lamps/bulbs, where a screw into sheet metal provides the ground (I failed to expose metal through the epoxy/urethane layers in sheet metal/etc).

scottss60 #1219326 05/30/2017 4:04 PM
Joined: Aug 2014
Posts: 307
S
'Bolter
'Bolter
S Offline
Joined: Aug 2014
Posts: 307
Wow, surprised about the ground issue. I am installing a radio what would be the best way to ground that? I have a 12 volt 1/2 ton. THanks, Scott

scottss60 #1219331 05/30/2017 4:22 PM
Joined: Feb 2004
Posts: 29,746
H
Kettle Custodian (pot stirrer)
Kettle Custodian (pot stirrer)
H Offline
Joined: Feb 2004
Posts: 29,746
Grounds are like the sewer or septic system in a municipal water supply- - - -they get the water back into the earth it came from. Ditto for auto electrics- - - -the electrons need a low-resistance path back to the battery to complete the circuit.
Jerry


"It is better to be silent and be thought a fool than to speak and eliminate all doubt!" - Abraham Lincoln
Cringe and wail in fear, Eloi- - - - -we Morlocks are on the hunt!
There is nothing noble in being superior to your fellow man; true nobility is being superior to your former self. - Ernest Hemingway
Love your enemies and drive 'em nuts!
Joined: Mar 2010
Posts: 10,270
5
Renaissance Man
Renaissance Man
5 Offline
Joined: Mar 2010
Posts: 10,270
Originally Posted by Hotrod Lincoln
Wouldn't it be better to attach that long cable directly to the engine, or maybe a bellhousing bolt? Then use a ground strap to the frame and/or the cab to handle such things as grounding the lights, voltage regulator, etc.


Jerry
Yes it would. That is exactly what I did on my '49 with a 350 in it. On my '50 (with a 235), I didn't want to lose the original look of the woven ground strap between the frame and the bellhousing bolt.


1952 5-window - return to "as built" condition | 1950 3100 with a 235 and a T-5 transmission
scottss60 #1219373 05/30/2017 8:11 PM
Joined: Sep 2001
Posts: 29,269
Bubba - Curmudgeon
Bubba - Curmudgeon
Joined: Sep 2001
Posts: 29,269
Originally Posted by scottss60
Wow, surprised about the ground issue. I am installing a radio what would be the best way to ground that? I have a 12 volt 1/2 ton. THanks, Scott
" . . . a ground strap from the head to the firewall (GM spec for radio) . . . "

I run a strap from the rearward coil mounting bolt/screw to one of the the passenger side fender-to-firewall bolts. The dash is connected to firewall, and the radio is connected to the dash. Presumably they will be bare-metal to bare-metal contact providing ground-continuity?

scottss60 #1219446 05/31/2017 4:34 AM
Joined: Mar 2011
Posts: 1,146
J
Shop Shark
Shop Shark
J Offline
Joined: Mar 2011
Posts: 1,146
Here is a ground question.(pertaining to lighting protection)

You have a TV antenna on the top of your roof.
There is 20 feet of coaxial cable coming from the TV antenna going down the siding to a coaxial cable ground block.
From the coaxial cable ground block there is 20 feet of coaxial cable that is going into the home and is connected to the back of the TV.
Also from the coaxial cable ground block there a single 19 foot, 10 gauge copper
ground wire that is connected to a 10 foot ground rod that is pounded into the ground.
The antenna mast is also grounded to the ground rod with 39 feet of 10 gauge copper ground wire.

If the TV antenna gets hit by lighting, is the TV protected?

jorb #1219449 05/31/2017 4:49 AM
Joined: Feb 2004
Posts: 29,746
H
Kettle Custodian (pot stirrer)
Kettle Custodian (pot stirrer)
H Offline
Joined: Feb 2004
Posts: 29,746
Originally Posted by jorb
If the TV antenna gets hit by lighting, is the TV protected?

Don't make any big bets on it. Millions of volts pushing thousands of amps at the speed of light has a tendency to overpower any sort of grounding system. When we were the last residence at the end of the power grid in our neighborhood we lost two deep well submersible pumps to lightning strikes. It seems the power surge from lightning hitting a transformer half a mile away on top of a tall hill liked a wet ground 300 feet deep with my pump hanging on the end of a pipe, and the pipe was plastic! No wiring damage, no tripped circuit breakers, just motor windings fused into a solid blob of burned copper!
Jerry


"It is better to be silent and be thought a fool than to speak and eliminate all doubt!" - Abraham Lincoln
Cringe and wail in fear, Eloi- - - - -we Morlocks are on the hunt!
There is nothing noble in being superior to your fellow man; true nobility is being superior to your former self. - Ernest Hemingway
Love your enemies and drive 'em nuts!
scottss60 #1219473 05/31/2017 1:50 PM
Joined: Aug 2000
Posts: 1,438
D
'Bolter
'Bolter
D Offline
Joined: Aug 2000
Posts: 1,438
I have surge protectors on my TV for that but they are no guarantee either but I figure they can't hurt.

Dennis


40 Chevy 1/2 ton
scottss60 #1219496 05/31/2017 5:49 PM
Joined: Aug 2014
Posts: 307
S
'Bolter
'Bolter
S Offline
Joined: Aug 2014
Posts: 307
by the way, I used a 4 gauge ground strap.

scottss60 #1219620 06/01/2017 4:01 PM
Joined: May 2005
Posts: 1,624
B
Shop Shark
Shop Shark
B Offline
Joined: May 2005
Posts: 1,624
Jerry, There is a 'trick' which may save your pumps in the future. I learned it when putting in earthquake monitoring systems for TVA. We had to to install the seismonitors on ridges due to us having to use 'line of sight' data transmission. Lighting would hit the solar panel or antenna and wipe out the electronics.
Learned to put a 'J' shaped loop in the coaxial and solar panel wire underground when it entered the electronic box. As lighting is moving at near the speed of light it tends to want to run straight. It would hit the 'J' curve and burn a hole through the insulation to reach ground. We also installed "Zapnots" on the front end of the electronics for the reduced electromagnetic spike. Yeah, we would lose a coaxial cable but not thousands of dollars of electronics.


Six volt guy living in a twelve volt world
scottss60 #1219634 06/01/2017 5:39 PM
Joined: Feb 2004
Posts: 29,746
H
Kettle Custodian (pot stirrer)
Kettle Custodian (pot stirrer)
H Offline
Joined: Feb 2004
Posts: 29,746
When the power company rewired the system in the neighborhood the last time an ice storm took all the lines down, we're no longer at the end of one circuit. No problems recently, other than when one of the neighbors spits a chaw of tobacco off his back porch, the moisture shorts out the power grid! The Fayetteville electric system is notorious for having rain and thunderstorm outages! Those kerosene lamps in various places around our house are not decorative. We keep 'em filled with oil and the wicks trimmed all the time.

It's a small price to pay for being 20 miles from the nearest town big enough to have a WalMart and public housing, though!
Jerry


"It is better to be silent and be thought a fool than to speak and eliminate all doubt!" - Abraham Lincoln
Cringe and wail in fear, Eloi- - - - -we Morlocks are on the hunt!
There is nothing noble in being superior to your fellow man; true nobility is being superior to your former self. - Ernest Hemingway
Love your enemies and drive 'em nuts!

Moderated by  Jon G, Rusty Rod 

Link Copied to Clipboard
Home | FAQ | Gallery | Tech Tips | Events | Features | Search | Hoo-Ya Shop
Powered by UBB.threads™ PHP Forum Software 8.0.0