Hy sansaba1948, you can connect a wire from the "R" terminal on the starter solenoid directly to the coil positive terminal, when the engine is not being cranked to start the "R" terminal is not connected to anything else. You will have to run a wire from the ignition switch to the ballast resistor (if required) or directly to the coil, hope that helps.