The safest way to polarize a generator is to disconnect the Armature lead from the regulator connection, and flash it to the Battery terminal for a moment. Some people just short a screwdriver blade between the two terminals, but I've seen regulators damaged that way. It's safer to disconnect the "A" lead. Just a quick flash is all that's necessary, less than a second of contact. A properly polarized generator should develop about 2 volts at the Armature terminal with the engine running, and the armature and field leads disconnected.
Jerry


"It is better to be silent and be thought a fool than to speak and eliminate all doubt!" - Abraham Lincoln
Cringe and wail in fear, Eloi- - - - -we Morlocks are on the hunt!
There is nothing noble in being superior to your fellow man; true nobility is being superior to your former self. - Ernest Hemingway
Love your enemies and drive 'em nuts!