Thanks for your help here’s some more info


1. When was motor last running? Recent?...never yet?

A few weeks ago. It’s been getting harder to start over last month or so

2. Was running and then you posted this? I hope the scenario is "Motor won't start, so I checked spark, no spark" Is that right???

Yes wouldn’t start and I checked for fuel and spark


3. Most times it's that the person thinks the point gap is correct and it's not. So close gap a little. Try. No spark? open gap a little.

I set points correctly I think but I also varied it a lot so see if I could get a spark and nothing


4. Next common issue: bad new condenser.

I have 12.4v in and 8.35v out when points closed and 12.4v both sides when open

5. Next common issue: you took the dizzy out and didn't get it back correctly.

Checked

6. Next, timing off...same as 5.


I haven’t touched the timing at least not deliberately…and it was running ok before for most part

Last edited by Drmike; 08/16/2025 10:35 PM.